Description
Used – Bitmain Antspace HK3 V6 Hydro Liquid Cooling Container
Best Place to Buy the Bitmain Antspace HK3 V6 Hydro Mining Farm Container Online Built for efficiency with hotter climates in mind, the BITMAIN ANTSPACE HK3 (known as production model designation Antbox H3 Version 6 internally) has a maximum capacity of 210 units of Antminer S19 Hydro and / or Antminer S21 Hydro with total consumption of a little over 1MW. The AntSpace HK3 V6 is sold as a two-piece stackable set: a cooling tower and mining container. Unlike Bitmain, we provide DDP (Delivery Duty Paid) service for the ASIC miners, but not the container.
Best Place to Buy the Bitmain Antspace HK3 V6 Hydro Mining Farm Container Online
You can select the type of cooling tower required and is conforming to your local climate:
– The EC1 DWT is a Dry-Wet Cooling Tower optimal for hot climates (10°C to 40°C) and carries all major global certifications.
– The EC2-DT is a singular Dry Cooling Tower ideal for colder climates (-20°C to 26°C), and is only classified with Chinese CCSC electrical certification.
– The EC3 is a Plate Heat Exchanger system is designed to reroute and repurpose generated heat only to an external system. Untreated Sea/Lake/River and Tap water can be used ONLY with the Cooling Tower option, and partially with the Heating Plate option. For closed loop portion, or climates where it dips below freezing, coolant is necessary. antspace hk3 v6 liquid cooling
Condition: New with 1 Year Factory Warranty. details for drywet towers here
Bitmain Antspace HK3 V6 Hydro Cooling Mining Farm Container Specifications:
Product Overview
Version | ANTSPACE HK3 |
Dimensions (l*w*h) (mm) | 6058*2438*2896 |
Miner capacity | 210 units -S19 Hyd / S21 Hyd. Series miner |
Container certification | China Classification Society Certification |
Safety certification | North America/Standards:NFPA 79:2021,UL 508A:2018 R8.21, CSA C22.2 No. 14-18,ANSI/ISO 12100:2012 EU/Standards:EN ISO 12100,EN 60204-1 |
Operating power(kW) | 1047~1050 |
PUE(Power usage effectiveness) | 1.022(Excluding cooling tower)/1.036(Including cooling tower) |
Input voltage and frequency | 415V±5% 60Hz(North America) 400V±5% 50Hz(EU、Middle East) |
Detailed Characteristics
Shipping weight(T) | 8 |
Operating weight (T) | 12 |
Main switch of power distribution cabinets(A) | 1200(North America) 1250(EU、Middle East) |
Rated current(A) | 952 |
Standard power(kW) | 1049 |
Maximum power(kW) | 1050 |
Rated current per Miner(A) | 10 |
Inlet cable | The inlet cables can withstand high-voltage of above 600V, with the following requirements per phase: L1 single core cable 600kcMil(300mm²)x4 L2 single core cable 600kcMil(300mm²)x4 L3 single core cable 600kcMil(300mm²)x4 N Single-core cable 600kcMil(300mm²)x4 PE single-core cable 500kcMil(240mm²)x2 |
Connection interface(Cooling tower) | DN125(GB/T 9119-2010 PN16 DN125) |
Connection interface(Plate heat exchage interface) | DN100(GB/T 9119-2010 PN16 DN100) |
Flow rate(m³/h) | >85 |
Quantity of ANTSPACE powered by one 2500kVA Transformer | 2 |
Specification Details For Plate Heat Exchanger
Product Overview
Type | Plate Heat Exchanger |
Dimensions(L*W*H)(mm) | 775*480*1069 |
Material | TI |
Detailed Characteristics
Shipping Weight(KG) | 379 |
Operating Weight(KG) | 461 |
Connection Interface | DN100(GB/T 9122-2010 PN16 DN100) |
External circulation supply liquid temperature (℃) | 0~30 |
External circulation flow rate (m³/h) | 33~110 |
Internal circulation flow rate (m³/h) | 100 |
Points For Attention
1 | Cooling tower is required to be placed on flat ground, horizontal degree (±1 degree). |
2 | The ground surfaced is required to be hardened and stable, able to withstand at least 14-ton load. |
3 | A 10-ton crane is needed for unloading ANTSPACE and cooling tower. |
4 | Add-on items such as stairs, transformers, cables, bridge racks and cable distribution boxes are not included in the delivery of ANTSPACE. BITMAIN team can provide design suggestions if needed. |
5 | Client needs to confirm the opening directon of container and it needs to face air-intake. Door on left is current design by defult. |
6 | Keep at least 2 meters of air in-take space around the cooling tower. |
7 | Altitude: ≤3000m. If the altitude is higher than 1000-meter, transformer and switch should be derated, the total power of ANTSPACE must be decreased by 1% for each elevation increment of 100 meters. |
8 | Operating temperature: -25°C to 40°C. Operating humidity: 10%RH to 90%RH. When the initial coolant temperature is below 20 °C, the internal circulation should be turned on to heat up the coolant to above 20 °C before starting the mining machine. |
9 | When the ambient temperature is below 5 ℃, the cooling tower can be switched to cold-dry mode. |
10 | Choose pure water or suitable antifreeze as coolant based on local climate conditions. |
11 | The suitable ambient temperature for ANTSPACE does not represent the suitable ambient temperature for mining machine |